Ultrasonic Thickness Gauge GM-100
| Cat. No. | Size / model | Qty | Add |
|---|---|---|---|
| GM-100-S1 | Small | ||
| GM-100-S2 | Large | ||
| GM-100 | 1.2 ~ 225.0 mm (Steel), 0.1 mm, ±(1%H+0.1) mm (H denotes measured thickness of the object), Four-digit LCD display, 5 MHz, Range: 1000 to 9999 m-s, Ø |
AVAIN LABS® Ultrasonic Thickness Gauge GM-100
The AVAIN LABS® Ultrasonic Thickness Gauge GM-100 is a compact and convenient ultrasonic thickness measuring instrument designed for non-destructive measurement of material thickness. It is particularly suitable for measuring the thickness of steel components, tubes, pipes, tanks, and other suitable solid materials without cutting or damaging the test object.
With a measuring range of 1.2 to 225.0 mm for steel, 0.1 mm resolution, and a clear four-digit LCD display, the GM-100 provides a practical solution for thickness inspection and routine measurement applications.
Key Features
- AVAIN LABS® Ultrasonic Thickness Gauge GM-100
- Ultrasonic, non-destructive thickness measurement
- Measuring range: 1.2–225.0 mm (Steel)
- Resolution: 0.1 mm
- Accuracy: ±(1%H + 0.1) mm
- Clear four-digit LCD display
- 5 MHz working frequency
- Sound velocity range: 1000–9999 m/s
- Minimum tube measurement: Ø 20 × 3 mm (Steel)
- Sound velocity can be adjusted when the material thickness is known
- Compact and portable design
- Operates on 3 × 1.5 V AAA batteries
Non-Destructive Thickness Measurement
The AVAIN LABS® GM-100 Ultrasonic Thickness Gauge uses ultrasonic measurement technology to determine material thickness without damaging or cutting the test object. This makes it useful for inspection and measurement of suitable steel components and structures.
Measuring Range & Resolution
The GM-100 provides a measuring range of 1.2 to 225.0 mm for steel, with a resolution of 0.1 mm. This makes the instrument suitable for a variety of routine thickness measurement requirements.
Adjustable Sound Velocity
The instrument offers a sound velocity range of 1000 to 9999 m/s. When the thickness of the test material is known, the sound velocity can be adjusted to suit the material, providing greater flexibility for thickness measurement applications.
Tube Measurement
The minimum tube measuring specification is Ø20 × 3 mm (Steel), making the GM-100 suitable for thickness measurement applications involving appropriately sized steel tubes.
Technical Specifications
| Specification | Details |
|---|---|
| Product Name | Ultrasonic Thickness Gauge |
| Model | GM-100 |
| Brand | AVAIN LABS® |
| Measuring Range | 1.2–225.0 mm (Steel) |
| Resolution | 0.1 mm |
| Accuracy | ±(1%H + 0.1) mm |
| Display | Four-Digit LCD Display |
| Working Frequency | 5 MHz |
| Sound Velocity | 1000–9999 m/s |
| Minimum Tube Measurement | Ø20 × 3 mm (Steel) |
| Sound Velocity Setting | Adjustable with known thickness |
| Operating Temperature | 0–40°C |
| Power Supply | 3 × 1.5 V AAA Batteries |
| Dimensions | 72 × 146 × 29 mm |
Applications
The AVAIN LABS® Ultrasonic Thickness Gauge GM-100 can be used for suitable thickness inspection applications including:
- Steel thickness measurement
- Tube and pipe thickness measurement
- Metal component inspection
- Non-destructive testing
- Engineering inspection
- Manufacturing and fabrication
- Maintenance and quality control
- Laboratory and technical applications
- General material thickness measurement
Compact & Portable Design
With dimensions of just 72 × 146 × 29 mm, the GM-100 is designed for convenient handling and portability. Its battery-powered operation makes it practical for use in different inspection and measurement environments.
Why Choose AVAIN LABS® GM-100?
The AVAIN LABS® GM-100 Ultrasonic Thickness Gauge combines a 1.2–225.0 mm measuring range, 0.1 mm resolution, 5 MHz working frequency, adjustable sound velocity, and compact four-digit LCD display in a portable instrument.
Choose AVAIN LABS® GM-100 for convenient ultrasonic, non-destructive thickness measurement of suitable steel materials, tubes, and components.
| Cat. No. | Size / model | Size | Measuring Range | Resolution | Accuracy | Display | Working frequency | Sound Velocity | Minimum limit for tube measuring | Features | Measuring range by known thickness | Operating temp. | Power Source | Dimensions |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| GM-100-S1 | Small | Small | - | - | - | - | - | - | - | - | - | - | - | - |
| GM-100-S2 | Large | Large | - | - | - | - | - | - | - | - | - | - | - | - |
| GM-100 | 1.2 ~ 225.0 mm (Steel), 0.1 mm, ±(1%H+0.1) mm (H denotes measured thickness of the object), Four-digit LCD display, 5 MHz, Range: 1000 to 9999 m-s, Ø | - | 1.2 ~ 225.0 mm (Steel) | 0.1 mm | ±(1%H+0.1) mm (H denotes measured thickness of the object) | Four-digit LCD display | 5 MHz | Range: 1000 to 9999 m-s | Ø 20 x 3 mm (Steel) | Inverse sound velocity with known thickness | 1000 to 9999 m-s. (Thickness of the test block must be less than 20 mm to measure speed of sound) | 0 to 40°C | 3 x 1.5 V (AAA) | 72 x 146 x 29 mm |
- Add the sizes and quantities you need to your quote list and send it - we reply with a proforma invoice.
- Orders are dispatched by courier or transport across India; you get the tracking number by email.
- A GST tax invoice is issued with every order. Bulk and institutional orders are welcome.
- Dealers: register here for dealer prices and online ordering.
- Questions? Read our FAQ or contact us.
Recently viewed
Request a call back
About Ultrasonic Thickness Gauge GM-100 (GM-100). Our team will call you shortly.